Home > Buy Now > Transformers > Single Phase DG Isolation Transformer
 


Guangzhou Yongxiang Electrical Appliance Factory
 
icon Products

line

icon Company Profile
icon Selling Leads

line

 
Contact us
Guangzhou Yongxiang Electrical Appliance Factory
[China]
Address:
No.128, Miaozai Zhuang, Jiannan Village, Banghu Town, Baiyun District Guangzhou Guangdong China
Phone:
86-020-86039861
Contact name:
Ellie He
Inquire now










Guangzhou Yongxiang Electrical Appliance Factory



 
Products

Single Phase DG Isolation Transformer

Inquire now

Single Phase DG Isolation Transformer

Click to enlarge image


Single Phase Isolation Transformer
Isolation Transformers have primary and secondary windings that are physically separated from each other. Sometimes isolation transformers are referred to as "insulated".
This is because the windings are insulated from each other. In an isolation transformer the output winding will be isolated, or floating from earth ground unless bonded at the time of installation. Secondary neutral to ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades.

Application:
This single phase isolation transformer is widly applied to the single phase power supply of import-export equipment,safe-isolation power supply,step up-step down power supply,rectifier equipment power supply,detecting system power supply,and kinds of machinery power supply.(The mode of connection can select lead wire,raw copper wire,connection,brass screw of input and output voltage is less than 1000V)

Basic Data
Primary/Secondary Voltage:220/220V  220-380V
Rated Power : 50VA-100KvA
Rated Frequency:50/60Hz
Cooling method:naturel air or forced air cooling
Ambinet temperaturer:-50 to 40 Celsius Degree
Isoaltion systerm : B ,F , H

Operating environment
1)Temp.:The ambient temperature can not over +40℃。
2)Altitude: Mounting location can not exceed the altitude of 2000m
3)Relative humidity: Maximum 90%
4)The site not attack by rain and snow
5)The medium which no explosion danger, no corroding metal, no electrical breakdown

Testing Items:
No-load Test(No-load Current, No-load Voltage, No-load Loss)
Load Test (Load Voltage, Temperature-rise)
Inductive Voltage Test
DC Resistance Test
Safety Test

 

Comparison on Transformer with Toroidal, EI, R, CD Shape Core
Since 1995, we have been playing a leading role to replace the types of R, CD, EI with toroidal type for our customers from each part of the world.
Core EI, R & CD Toroidal
Dimension Not Adjustable Adjustable
Performance Average Better
Reliability Average Better
Price Expensive 10%-30% Cost Saved

Productivity:
Toroidal/annular/ring transformer 2 million PCS,
EI transformer 3 million PCS annually;
Three Phase Transformer 50000pcs
Others 100000 pcs

Workforce:
About 200 workers, 5 technicians, 2 senior engineers

Equipment:
Over 50 sets toroidal/annular/ ring coil winding machines, 3 EI type transformer lines, 2 sets of vacuum annealing furnaces, A set of nitrogen and hydrogen production equipment.

Warning
Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.

Label Info:
Certificate Logo, Basic Electronic Data, Manufacture's Information, also can be printed according to customer's Advice.
Bar Code available according to customer's advice.

Certificate:
The certificate of our transformer has CE CQC RoHs UL

Note:
The above-mentioned single phase Isolation transformer is frequently-used, we can also manufacture the products by customer design. And the specification is for reference, if has the change further, please take the material object as the standard.




Inquire now